Download
Brochures

DEXUP Fluid Warmer (Dual Channel System)

A compact and high-precision fluid warming system designed to rapidly warm blood and IV fluids, helping prevent hypothermia during transfusion and infusion procedures. Its dual-channel design ensures efficient and consistent temperature control for critical care environments.

Applications:

Blood Transfusion

High Volume Infusion Therapy

ICU & Critical Care

Operation Theatres

Emergency & Trauma Care

Neonatal & Pediatric Care

A light, ergonomic design and convenient trolley mounting options make the Blanket Warming Unit a desirable choice for patient warming needs.

Features
Device Specifications

Dual Channel Heating
Simultaneously warms fluids through two independent heating channels for faster and efficient performance.

Precision Temperature Control
Adjustable temperature range from 32°C to 43°C with fine control for safe and accurate warming.

Rapid Heating System
Quickly raises fluid temperature to desired levels, reducing patient heat loss.

Lightweight & Portable Design
Lightweight and portable design for easy manoeuvrability.

Intelligent Display Interface
Shows real-time temperature, set values, working time, and system status.

Advanced Safety Protection
Built-in high & low temperature alarms, overcurrent protection, and automatic shutdown for patient safety.

Compact & Portable
Lightweight (~1 kg) design makes it easy to use in ICU, OT, and emergency setups.

Parameter Specification
Model DEXUP FW D 100
Design Control device with 2 heating silicon tubes
Temperature Setting Range 32°C-43°C (0.1°C step)
Liquid Outlet Temperature Deviation ±2.0°C
Heating Time From 23 ± 2°C to 36°C in a short time
Display Parameters Current temperature, Set temperature, Running/Working time, Channels, Alarm mute, Seek
Safety - High Temperature Protection Alarm and stop if temperature reaches 45°C for 30s or exceeds set temperaturo by> 8°C
Safety - Low Temperature Protection After 5 minutes from startup, if tube temperature $30°C, alarm and stop
Overcurrent Protection Dual input fuse circuit (Fuse: 5T 4A/250V)
Fault Indication Display shows fault codes and fault information
Power Supply 220 VAC, 50 Hz, 4 A
Power Cord 5.0 m, 250 V, 10 A
Display Size 4.3 inches
Weight Approx. 1 kg
Dimensions (cm) 15 (W) x 7.5 (D) x 20 (H)
Service Life 5 years
Operating Environment Temperature: 5-30°C; Humidity: 30-75% RH; Pressure: 700-1060hPa
Standard Accessories

Fluid Warmer x1;

Heating Silicon Tube x2; Detachable Power Cord x1; User Manual x1

Application Immediate heating of blood transfusion or infusion fluids:
reduces temperature difference between liquid and patient's body to prevent hypothermia

Get In Touch With Us